Revista Panamericana de Salud Pública, Volume: 3, Número: 5, Publicado: 1998
  • The use of capture-recapture methods to monitor diabetes in Dominica, West Indies Articles

    Tull, Eugene S.; Butler, Cleve; Gumbs, Leyale; Williams, Sherida

    Resumo em Espanhol:

    El propósito de este trabajo fue evaluar la utilidad de la metodología de estimación por captura y recaptura (CR), aplicada junto con fuentes de información fácilmente accesibles, para monitorear la frecuencia de diabetes mellitus en un país en desarrollo. En la isla caribeña de Dominica, se recogieron de julio de 1995 a julio de 1996 los nombres de todas las personas que figuraban como mínimo en una de tres fuentes diferentes por haber recibido un diagnóstico de diabetes en el transcurso de 1995. Las fuentes fueron la lista de miembros de la Asociación de Diabetes de Dominica, un registro de los pacientes atendidos en siete centros de salud regionales y las fichas clínicas del Hospital Princess Margaret, que es el más importante de la isla. Se aplicaron técnicas de CR para estimar el número de dominicanos con diabetes diagnosticada que no fueron detectados por ninguna de las tres fuentes, y para evaluar las discrepancias entre las distintas fuentes. Se procedió a calcular la prevalencia estimada de diabetes diagnosticada, corrigiéndola según los datos obtenidos. Las tres fuentes identificaron a un total de 1 945 individuos diferentes. Cuando se comparó con la estimación corregida que se obtuvo por el método de CR (2 688), se observó que esta cifra representaba solamente 72,3% de la verdadera prevalencia de diabetes diagnosticada. La mayor parte de la subdetección en las fuentes de datos correspondió a casos que no fueron captados en la zona urbana de la isla. Esta forma de monitorear la enfermedad podría resultar útil en otros países caribeños. No obstante, hacen falta procedimientos estandarizados de recolección y notificación de datos sobre prevalencia y morbilidad para lograr que este enfoque rinda al máximo en exactitud y costo-efectividad.

    Resumo em Inglês:

    The aim of this project was to evaluate the utility of capture-recapture (CR) estimation methodology, together with easily accessible sources of information, for monitoring the frequency of diabetes mellitus in a developing country. On the Caribbean island of Dominica, from July 1995 through July 1996, the names were collected of all individuals who were listed in at least one of three sources as having been diagnosed with diabetes during 1995. The sources were the membership list of the Dominica Diabetic Association, a register of patients in seven regional health centers, and clinic records of the Princess Margaret Hospital, which is the main hospital on the island. Capture-recapture techniques were used to estimate the number of Dominicans with diagnosed diabetes who were missed by all three sources of information and to evaluate dependencies among the sources. An ascertainment-corrected prevalence estimate of diagnosed diabetes was then calculated. The three sources identified a total of 1 945 different individuals. When this number was compared with the ascertainment -corrected estimate obtained with CR methodology (2 688), it appeared to represent only 72.3% of the true prevalence of diagnosed diabetes. Most of the under-ascertainment by the data sources was due to cases that were missed in the urban area of the island. This approach to disease monitoring may be useful for other Caribbean countries. However, standardized procedures for collecting and reporting prevalence and morbidity data are needed to maximize its accuracy and cost-effectiveness.
  • Flit-gun sprayer characteristics Articles

    Brown, J. R.; Williams, D. C.; Gwinn, T.; Melson, R. O.

    Resumo em Espanhol:

    Se pusieron a prueba seis atomizadores de compresión activados a mano a fin de evaluar su utilidad para programas de exterminio de mosquitos adultos en que se necesiten tecnologías no motorizadas de bajo costo. Se hace un análisis de la varianza en cuanto a partículas <= 24 y > o = 48 micras (µ), partículas/cm², diámetro del volumen mediano, y número de mosquitos muertos. Los datos confirman que pueden obtenerse buenos resultados con aparatos de este tipo.

    Resumo em Inglês:

    Six flit-gun sprayers were tested for possible use in mosquito adulticide programs where inexpensive nonmotorized application technology may be required. An analysis of variance for differences in droplets <= 24 microns (µ), droplets > or = 48 µ, droplets/cm², volume median diameters, and mosquito mortality is provided. As shown by these data, good results can be achieved with this equipment.
Organización Panamericana de la Salud Washington - Washington - United States
E-mail: contacto_rpsp@paho.org